Product Specifications
Model | |
Brand | TRIPP LITE |
Model | SU10000RT3U2TF |
Input | |
Input Voltage Range | 208V & 120V AC |
Input Frequency | 50/60 Hz |
Output | |
VA Rating | 10000 VA |
Watts | 8000 Watts |
Output Voltage | 208V & 120V AC |
Outlets | 2 x NEMA L6-30R, 4 x NEMA L6-20R, 24 x NEMA 5-15/20R |
Battery | |
Battery Run Time | Full load runtime: 6 min. (10,000VA/8000W) Half load runtime: 12 min. (5000VA/4000W) |
Battery Recharge Time | 2-8 hours to 90% |
Spec | |
Interface Port | RS-232 |
Management Software | YES |
Approvals | Tested to UL1778 (USA), CSA C22.2 No. 107.3 (Canada), CE (European Union), NOM (Mexico), Class A (Emissions) |
Physical Spec | |
Rackmountable | Rack/Tower (10U) |
Weight | Power Module (54.8), Step-down Transformers (60), Battery Pack (158.7) |
Dimensions | Power Module 5.14 x 17.5 x 25, Step down transformers 3.5 x 17.5 x 20.8, Battery Pack 5.16 x 17.5 x 25 (Installed depth of power module extends to 32.5 inches once detachable PDU backplate is installed) |
Features | |
Features | 10,000 VA on-line, double-conversion UPS system (high voltage input/high AND low voltage output) Detachable input-output PDU module with manual bypass switch enables hot-swap UPS replacement without powering off connected equipment Installs in only 10 rack spaces (3U power module, 3U battery pack, 2 x 2U step-down transformers) with a maximum installed depth of 32.5 inches Offers 6 min. runtime at full load (10,000VA/8000W) and 12 min. at half load (5000VA/4000W). Runtime is expandable with any number of optional BP240V10RT3U external battery packs Full-time sine wave 208V and simultaneous 120v +/-2% output Actively converts raw incoming AC power to DC, then re-converts output back to completely regulated, filtered AC output Operates continuously without using battery power during brownouts to 156V and overvoltages to 276V Standard 3-wire 208V hardwire input connection 2 NEMA L6-30R, 2 L6-20R and 24 5-15/20R output receptacles Detailed LCD panel with scroll buttons offers detailed diagnostic test Network-grade AC surge and noise suppression Zero transfer time between AC and battery operation Includes slot for internal SNMP/web card, plus DB9 enhanced serial monitoring port, and contact closure port for unattended shudown, remote control and monitoring of UPS system and power data Supports detailed monitoring of equipment load levels, self-test data and mains power conditions via network interfaces. Includes PowerAlert monitoring software and complete cabling Emergency Power Off (EPO) interface Front panel LEDs offer at-a-glance confirmation of line power status, battery power status, AC-to-DC & DC-to-AC conversion, bypass mode and output power status. Fault-tolerant auto-bypass mode prevents loss of output during UPS fault conditions or excessive UPS loading 4-post rackmount and upright tower installation accessories included; 2POSTRMKITWM 2-post rackmount hardware accessories available |