TrippLite SMARTONLINE Series 8kVA On-Line Double-Conversion UPS
When power interruptions occur, protect both your equipment and operations with the TrippLite SMARTONLINE Series 8kVA On-Line Double-Conversion UPS. The TrippLite SMARTONLINE Series 8kVA On-Line Double-Conversion UPS is ideal equipment to secure for your business, keeping your critical network servers running continuously when blackouts and power failures occur. You don?t have to worry about losing data or your equipment failing either as it comes with zero transfer time. This UPS also features a detachable PDU with manual bypass switch, allowing hot-swappable UPS power module replacement with no interruption in output power to connected networking equipment. Purchase the TrippLite SMARTONLINE Series 8kVA On-Line Double-Conversion UPS today!
What It Is And Why You Need It:
- 8kVA/8000VA/7200W on-line double-conversion UPS; offers complete power protection for critical network applications
- Expandable Runtime with Optional External Battery Packs; supports several external battery packs
- Fault-tolerant Auto-bypass; prevents unexpected service interruption during UPS overload or internal fault conditions
- Detachable PDU with Manual Bypass Switch; enables hot-swappable replacement of entire UPS power module with no interruption to connected equipment
A Closer Look:
Product Specifications
Model | |
Brand | TRIPP LITE |
Series | SmartOnline |
Model | SU8000RT3UN50TF |
Output | |
VA Rating | 8000 VA |
Watts | 6400 Watts |
Output Voltage | Maintains pure sine wave output at all times, regulated within 2% of selected nominal output voltage, less than 3% total harmonic distortion when used with computer loads |
Outlets | 18 |
Outlet Type | 4 NEMA L6-20R 2 NEMA L6-30R 12 NEMA 5-15/20R |
Battery | |
Battery Run Time | Full load runtime 6 min. (8000VA/6400W) Half load runtime 15 min. (4000VA/3200W) |
Battery Recharge Time | Less than 8 hours to 90% (included battery set only) |
Spec | |
Alarms | Multi-function audible alarm offers notification of UPS start, backup operation, low battery, overload, UPS fault, inverter fault, DC bus fault, overtemperature, remote shutdown, shutdown imminent and shutdown complete |
Interface Port | Includes 2 built-in DB9 monitoring ports (1-RS232 / 1-contact closure) |
Approvals | Tested to UL1778 (USA), CSA C22.2 No. 107.3 (Canada), CE (European Union), NOM (Mexico), Class A (Emissions), RoHS Compliant |
Physical Spec | |
Rackmountable | 8U |
Weight | Power Module 55 lbs. Battery Pack: 136.5 lbs. Step-down transformer: 57 lbs. |
Features | |
Features | Applications Ideal for protection of sensitive electronics in any application calling for upright tower or 19 inch rackmount UPS protection. Common applications include any mix of servers, workstations, hubs, routers, concentrators, IP telephony and traditional PBX switching systems Detachable input-output PDU module with manual bypass switch enables hot-swap UPS replacement without powering off connected equipment Installs in only 8 rack spaces (3U power module/3U battery pack/2U step-down transformer) with a maximum installed depth of 32.5 inches Full-time sine wave 208V and simultaneous 120V +/-2% output Actively converts raw incoming AC power to DC, then re-converts output back to completely regulated, filtered AC output Operates continuously without using battery power during brownouts to 156V and overvoltages to 276V Includes Hubbell twist-lock 50A AC input plug for simple installation; input cordset is removeable to support professional hardwire installation Detailed LCD panel with scroll buttons offers detailed diagnostic test Network-grade AC surge and noise suppression Zero transfer time between AC and battery operation Includes slot for internal SNMP/web card, plus DB9 enhanced serial monitoring port, and contact closure port for unattended shudown, remote control and monitoring of UPS system and power data Supports detailed monitoring of equipment load levels, self-test data and mains power conditions via network interfaces. Includes PowerAlert monitoring software and complete cabling Emergency Power Off (EPO) interface Front panel LEDs offer at-a-glance confirmation of line power status, battery power status, AC-to-DC & DC-to-AC conversion, bypass mode and output power status. Fault-tolerant auto-bypass mode prevents loss of output during UPS fault conditions or excessive UPS loading 4 post rackmount and upright tower installation accessories included. 2POSTRMKITWM two post rackmount hardware accessories available |